Legionella pneumophila as a Health Hazard to Miners: A Pilot Study of Water Quality and QMRA

by
Valerie Madera-García
1,*,
Alexis L. Mraz
2,
Nicolás López-Gálvez
1,
Mark H. Weir
3,
James Werner
1,
Paloma I. Beamer
1 and
Marc P. Verhougstraete
1
1
Department of Community, Environment, and Policy, Mel and Enid Zuckerman College of Public Health, The University of Arizona, Tucson, AZ 85724, USA
2
Department of Epidemiology and Biostatistics, College of Public Health, Temple University, Philadelphia, PA 19122, USA
3
Division of Environmental Health Sciences, College of Public Health, The Ohio State University, Columbus, OH 43210, USA
*
Author to whom correspondence should be addressed.
Water 2019, 11(8), 1528; https://doi.org/10.3390/w11081528
Submission received: 4 July 2019 / Revised: 19 July 2019 / Accepted: 20 July 2019 / Published: 24 July 2019
(This article belongs to the Special Issue Health Risks of Alternative Water Sources)

Abstract

:
Legionella pneumophila (L. pneumophila), the causative agent of legionellosis, is an aquatic bacterium that grows in warm water. Humans are only presented with a health risk when aerosolized water containing L. pneumophila is inhaled. In mining operations, aerosolized water is used as dust control and as part of the drilling operations, a currently ignored exposure route. This study characterized L. pneumophila concentrations in the mine’s non-potable water and the relationship between L. pneumophila and chlorine concentrations. These concentrations informed a quantitative microbial risk assessment (QMRA) model to estimate the infection risk to miners exposed to aerosolized water containing L. pneumophila. Fourteen water samples were collected from seven locations at a mine and analyzed for temperature, pH, chlorine, and L. pneumophila serogroup. Most samples (93%) tested positive for L. pneumophila cells. The faucet from the sprinkler system on the adit level (entrance to the underground mine levels) showed the highest concentration of L. pneumophila (8.35 × 104 MPN/L). Disability adjusted life years (DALYs) were estimated in the QMRA model and showed that the risk for all miners was significantly lower (p < 0.0001) with the ventilation system on than when the system was off. Our study showed that the use of a ventilation system at the adit level of the mine reduced the risk of infection with aerosolized L. pneumophila.

1. Introduction

Legionella pneumophila (L. pneumophila), a gram-negative, aquatic facultative bacterium is an intracellular parasite which multiplies in 13 species of amoeba commonly found in water-associated biofilms [1]. The bacterium thrives in large-premise plumbing systems as it colonizes biofilms and grows in warm water with temperatures between 25 and 45 °C [2,3,4]. Previous studies have reported the colonization of large water systems (e.g., hospitals and hotels) where L. pneumophila is dispersed via showerheads and faucets [3,5,6,7,8]. To cause illness, aerosolized L. pneumophila must be inhaled and deposited into the alveoli of the lung. Infection can result in legionellosis, a term which incorporates Legionnaires’ disease and Pontiac Fever [2,3,5,7,9]. L. pneumophila research has primarily focused on premise plumbing and cooling towers, which have shown an LD50 of approximately 100 organisms [10,11].
There are a variety of Legionella disinfection methods, with the most efficacious combining physical, chemical, and thermal methods [12]. Chemical methods, such as chlorination, must be effective in the elimination of water pathogens while leaving a residual level in the distribution system safe for human consumption. Chlorine is known to inactivate L. pneumophila in concentrations higher than those used in the domestic potable water (between 2 to 6 mg/L), and at temperatures above 41 °C [12]. Chlorine residuals dissipate throughout large-premise plumbing systems and decay faster at higher temperatures. Furthermore, chlorine residuals are shown to be less effective against bacteria residing in biofilms as the biofilm is impenetrable to the chlorine and the amoeba the bacteria utilize as host cells can be chlorine resistant [12]. There is limited knowledge regarding the persistence, distribution, and growth parameters of L. pneumophila in potable premise plumbing and water distribution systems. There is even less information on Legionella in non-potable water systems, such as misters and mines.
The extraction of minerals through mining activities is associated with the generation of dust, which is commonly controlled with aerosolized water [13]. Moreover, the quality of the water used in mining is often assessed based on environmental concerns, such as drainage into groundwater or the use of large open pits [14]. Concerns about the assessment of residual chlorine and water system maintenance in mine settings have not been addressed. A few studies have reported cases of Legionnaire’s disease among miners [15,16] and just one study tested water for L. pneumophila but failed to detect it [16]. Additionally, there are no published studies evaluating the risk of infection to L. pneumophila among mine workers using quantitative microbial risk assessment (QMRA).
QMRA is a computational science aimed at limiting infectious disease agents through an in-depth understanding of their biology and pathogenesis [17]. It has been proven effective for analytical and decision support in multiple exposure scenarios in various environmental medias, including air and water [18,19,20]. QMRA is a vital tool in understanding the risk in specific exposure scenarios and providing stakeholders with the information needed to make informed decisions on how to mitigate the potential for disease.
There is a lack of knowledge regarding the risk of legionellosis to miners. This study assessed the risk of exposure to L. pneumophila and the associated risk of a disability-adjusted life year (DALY) of miners exposed to aerosolized water using QMRA. A mine in southwest United States uses stored, non-chlorinated water for a dust-suppressing sprinkler system during mining activities in all working levels of the mine, resulting in the aerosolization of water. The non-potable water may remain in a non-covered storage tank for up to six months before being used or replaced. These practices can promote the growth of biofilms and L. pneumophila. This study characterized L. pneumophila concentrations in non-potable water used in the mine and the relationship between these L. pneumophila concentrations and chlorine in the water and then utilized a QMRA model to estimate the infection risk to miners exposed to aerosolized water containing L. pneumophila.

2. Methods

2.1. Site Description Section

This study was conducted at a 90-acre underground mine in the southwest region of the United States with four working levels and a depth of 250 feet. The facility has three water tanks: potable water, non-potable water, and non-potable water exclusively for firefighting. Each tank has a capacity of 22.7 m3, is refilled every 6 months, and none of the tanks receive any on-site chlorination treatment. A dust-suppressing sprinkler system drawing from the non-potable water tank was installed, but not utilized prior to the current study, resulting in stagnant water within the system. The jackleg drills at the studied mine utilized water from the non-potable water tank to abate dust and keep equipment clean, resulting in aerosolized water exposure to the surrounding workers. The non-potable water tank supplies the hoist house, adit level (first level on the interior of the mine), and underground levels. Seven sampling locations were chosen based on the water usage, storage conditions, potential exposure to aerosolized water, and proximity and accessibility to miners.

2.2. Sample Collection

Each selected location was sampled in duplicate in March 2017. A total of 14 water samples were collected for the L. pneumophila culture analysis. Temperature and chlorine levels were recorded for each sampling location. Multiple pipes distribute the water downstream from the non-potable water tank (Figure 1), through the adit level (entrance of the underground mine levels) and the exterior level (open field including the hoist house). The sampling locations included: the (A) sprinkler system on the adit level, (B) jackleg drill connection in adit level, (C) swamp cooler, (D) sink at hoist house, (E) jackleg drill hose at hoist house, (F) jackleg drill hose outside adit level, and (G) non-potable water tank.
Sterile, one-liter sealable plastic bottles, containing 0.1 N sodium thiosulfate, were used to collect approximately 1 liter of water after flushing the system for 1 min [21]. Water samples were collected from the non-potable tank by submerging one-liter plastic bottles directly into the tank. An additional water sample from each location was collected in a separate sterile plastic bottle to measure chlorine levels on-site using a pool chlorine test kit and temperature using a handheld thermometer [21]. All one-liter samples were immediately placed inside a cooler with ice packs to prevent rising temperatures and the potential growth of L. pneumophila due to the warm climate of Arizona. All samples were transported to the University of Arizona’s Medical Research Building (Tucson, Arizona, USA), and processed upon arrival.

2.3. Laboratory Analysis

The Legiolert® test kit by IDEXX was used to quantify L. pneumophila (detects 1 organism in 100 mL within 7 days) in non-potable water following manufacturer recommended methods, briefly described here [22]. A volume of 100 mL of deionized water and the content of a Legiolert® blister pack were added to a specimen container. Using a sterile microtube, 0.2 mL of Legiolert® Pretreatment and 0.2 mL of non-potable water sample were mixed and incubated at room temperature for 60 s (±5 s). Approximately 0.2 mL of the mix contained in the microtube was transferred to the specimen container. After mixing, the contents of the specimen containers were poured into Quanti-Tray/Legiolert® trays. The trays were immediately sealed in an IDEXX Quanti-Tray Sealer PLUS (IDEXX Laboratories, Inc., Westbrook ME, USA), and incubated paper-side down with the wells facing up at 37 ± 0.5 °C, 85% humidity for 7 days. For comparison, a negative control blank containing Legiolert® reagent and deionized water was incubated. Any sample that exhibited a brown color or a turbidity higher than the negative control was positive for L. pneumophila. A lack of brown color change and turbidity less than the negative control indicated a negative result. All the positive wells were counted to obtain the concentration in most probable number (MPN) as indicated by the Legiolert® MPN table (dilution factor = 0.0001).

2.4. Data Analysis

Arithmetic averages were calculated to summarize the concentrations of L. pneumophila. The concentration results were grouped into three categories based on their location (water storage level, adit level, and exterior level) to determine which areas represent a higher risk of exposure to miners. All analyses were performed using R [23].

2.5. QMRA

The QMRA focused on the sprinkler and jackleg drill, as these two systems aerosolize water known to contain L. pneumophila, therefore posing the highest risk of legionellosis to miners [23]. This model evaluated the risk of infection based on the concentration of aerosolized L. pneumophila as well as the probability of illness and the DALYs based on the risk of infection. According to the mine’s manager, the sprinkler system should be activated for 10 min prior to workers entering the mine and workers used the jackleg drill for 4-hour shifts up to twice a week. The concentration of respirable (≤5 µm) L. pneumophila (MPN/L) released into the mine from the sprinkler system every second (CL,air,S) was calculated following Equation (1), where CL,S is the L. pneumophila concentration in the non-potable water feeding the sprinkler system (MPN/L), PC is the air partitioning coefficient (unitless), VS is the volume of water released from the sprinkler (L/s), FA is the fraction of aerosolized organisms 1–5 µm (unitless), and Vm,air is the area of the mine (L).
C L , a i r , S = C L , S · P C · V s · F A V m , a i r
The concentration of respirable L. pneumophila (MPN/L) released into the mine due to the jackleg drill (CL,air,JD) was calculated using Equation (2), where CL,JD is the L. pneumophila concentration in the non-potable water feeding the jackleg drill (MPN/L), PC is the air partitioning coefficient (unitless), VJD is the flow of water released from the jackleg drill (L/s), FA is the fraction of aerosolized organisms 1–5 µm (unitless), and Vm,air is the area of the mine (L).
C L , a i r , J D = C L , J D · P C · V J D · F A V m , a i r
The mine utilizes a ventilation fan which removes ~5600 liters of air per second. The amount of L. pneumophila vented (Nvent) was calculated using Equation (3), where Vv is the volume of air the ventilation fan is removing from the mine (L) calculated using the fan flow rate over an 8-hour workday.
N v e n t = ( C L , a i r , S + C L , a i r , J D ) · V v
The L. pneumophila infectious dose to an individual (d) was calculated by summing the concentration of L. pneumophila in the mine per second the individual is assumed to be in the mine (one 4-hour shift) and multiplying the dose by the percentage of infectious L. pneumophila in a typical water system (10−4) and the inhalation rate utilizing Equation (4) [24]. Inhalation rates for male (Imale) and female (Ifemale) construction workers (m3/min) were used as construction was the most similar field to mine workers in the exposure factors handbook [25]. Equation (4) includes the concentration of respirable L. pneumophila into the mine from the sprinkler system during a shift, MPN/L (CL,air, S), the concentration of respirable L. pneumophila released into the mine due to the jackleg drill during a shift, MPN/L (CL,air, JD), the percent of L. pneumophila assumed infectious randomly selected from a uniform distribution of 0 to 1 (I), the inhalation rate, L/s (RI), and the amount of time a person is in the mine, seconds (t).
d = [ ( C L , a i r , S + C L , a i r , J D ) · I · R I · t ]   C v e n t
The daily infectious risk (Pi) was calculated using Equation (5), where k is the probability of the pathogen surviving to initiate infection in the host, and d is the inhaled dose calculated with Equation (4).
P i = 1 e k d
The probability of illness given infection was modeled using a simulated morbidity ratio (MR) due to the lack of a known morbidity ratio for the study’s diverse population. This MR is simulated using a uniform distribution parameterized from 0 to 1. Equation 6 shows the product used to calculate the probability of illness given infection (Pill). This Pill is then annualized (Pill,ann) using Equation (7) to calculate disability adjusted life years (DALYs) where j is progressed from 1 to the maximum number of exposure hours per year, assumed to be 400 h (4-h work shifts, 2 work shifts per week for 50 weeks per year, assuming 2 weeks off per year). DALYs (Equation (8)) were calculated utilizing the disability weights (DWs) presented in Table 1 for moderate infectious disease used to simulate Pontiac Fever (PF), severe infectious disease used to simulate Legionnaires’ disease (LD), and for post-acute consequences or sequela (e.g., long-term pulmonary damage).
P i l l = P i · M R
P i l l , a n n = 1 1 j ( 1 P i l l )
D A L Y = P i l l , a n n · D W

3. Results

3.1. Characterization of Legionella pneumophila Concentration

L. pneumophila was detected in 93% of the 14 water samples tested; one sample from the jackleg drill hose outside adit level was negative. Table 2 shows the results of temperature, chlorine levels, L. pneumophila average concentration at each sampling location, and the categorization of sampling locations based on the mine levels. The highest L. pneumophila average concentration, 8.35 × 104 MPN/L, was found in the sprinkler system on the adit level of the mine, where chlorine levels were below detection limit. The lowest L. pneumophila average concentration was found in the non-potable water tank that supplies all the tested sampling locations (1.50 × 104 MPN/L). The jackleg drill hose on the adit level of the mine had the highest temperature amongst all samples (30.9 °C).
After categorizing the sample locations based on the mine levels, the highest L. pneumophila average concentration (4.88 × 104 MPN/L) occurred on the adit level, where water aerosolization occurs through jackleg drilling and dust control with the sprinkler system (Figure 2). Therefore, a QMRA model was built to estimate the risk of exposure to aerosolized L. pneumophila on the adit level of the mine.

3.2. QMRA Model

The QMRA model describes the DALYs of male and female miners due to legionellosis based on L. pneumophila concentrations in the sprinkler and jackleg drill connections shown in Table 2. Male miners are at higher risk of legionellosis than female miners, as seen in the moderate, severe, and sequela DALYs (p < 0.0001). The ventilation system was effective at significantly lowering the moderate, severe, and sequela DALYs for both male and female miners (p < 0.0001) as shown in Figure 3, Figure 4 and Figure 5.
With the ventilation system off, DALYs ranged from 7.86 × 10−6 to 2.24 × 10−5. With the ventilation system on, DALYs were significantly lower (p < 0.001), with risk levels ranging from 1.81 × 10−6 to 8.79 × 10−6.

4. Discussion

This study characterized L. pneumophila concentrations in non-potable water used in the mine and estimated the infection risk to exposed miners using a QMRA model. L. pneumophila was detected in nearly all non-potable water samples. Furthermore, the highest average concentration of L. pneumophila was found in the sprinkler system on the adit level, which had not been previously used or flushed. L. pneumophila average concentrations were higher on the adit level compared to the other mine levels. Miners spend most of their work shift on this level and more water volume was observed to be used, which increases their risk of exposure to aerosolized L. pneumophila. There are no published reports which the authors are aware of that examines the presence of this bacterium in mine water.
A total of 86% of the locations sampled were found to have temperatures below the temperature range preferred for L. pneumophila growth (25–45 °C) [8]. Nevertheless, all tested locations were positive for the presence of L. pneumophila. The highest temperature, 30.9 °C, was measured at the jackleg drill hose outside the adit level which is consistently exposed to sun light. A typical dose of 0.1 to 10 mg/L of chlorine is effective and widely used against Legionella [12]. Approximately 71% of the sampling locations had chlorine residuals below detection limits, indicating a deficiency in chlorination of the non-potable water supply. One limitation of the study is that the Legiolert® test kit is designed to detect L. pneumophila but not to distinguish between serotypes. However, this is accounted for in the model by using the variable of the percentage of infectious L. pneumophila which includes all serotypes.
The QMRA shows male miners have higher DALYs due to legionellosis than female miners in all three categories (e.g., moderate, severe, and sequela), which corresponds to surveillance data showing men have higher incidences of legionellosis as compared to women [30]. In the QMRA, this result is directly linked to higher inhalation rates in males, leading to a higher potential dose of L. pneumophila. With or without the use of the ventilation system, male and female DALYs were above the acceptable risk of 1.0 × 10−6 in each category. DALYs results suggest that a lack of chlorine and the presence of L. pneumophila in non-potable water in the mine presents an unacceptable risk of legionellosis to miners. Considering non-potable water is used in the sprinkler system and jackleg drill, both of which produce aerosols, it is recommended that the water used for these activities be treated to avoid hazardous levels of L. pneumophila and reduce the risk of legionellosis to miners even if it is not intended for consumption.
Ventilation systems are often used to improve the quantity and quality of airflow throughout the underground mining levels by diluting and removing dangerous gases, reducing air temperature where mining machineries are being used, and providing airflow to unventilated areas [31,32]. In the current study, the mine’s ventilation system is only an exhaust fan. It does not represent a moisture control dynamic and should not be confused with HVAC (heating, ventilation, and air conditioning) systems, which some studies have demonstrated increase legionellosis risks in building settings [33,34]. Our study showed that the use of a ventilation system at the adit level of the mine reduces the risk of infection with aerosolized L. pneumophila. These results should be verified to be consistent for those mine ventilation systems which include moisture controls, that are more akin to HVAC systems.
Although the mechanism of the transmission of L. pneumophila can be difficult to identify, devices aerosolizing water have been involved in transmitting this bacterium to workers from a variety of occupational settings [35,36,37]. A literature review conducted on the cases of occupational legionellosis from 1978 to 2016 found that the workplaces most frequently associated with occupational legionellosis were industrial settings (62.0%), such as electrical power generation facilities, oil drilling, and automobile manufacturing, followed by office buildings (27.3%) and health care facilities (6.3%) [38]. Other workplaces, such as artesian excavation, horticultural sites, and sewage plants, reported sporadic cases of legionellosis [38]. The most prevalent sources of legionellosis infection in all workplaces were related to poorly maintained water sources such as coolant systems, cooling towers, spas, and vegetable misters [36,37,38,39]. To our knowledge, this is the first study that has detected L. pneumophila in a water system used in a mine setting. The findings of this study highlight the importance of maintaining and monitoring non-potable water sources that have the potential to produce aerosols. This study also highlights the risk of acquiring legionellosis in non-office environments. Even though there are no specific OSHA standards for the presence of L. pneumophila in occupational settings, this agency has a general duty clause of providing working environments free of known hazards related to the water sources and provide maintenance of all water systems to prevent growth of L. pneumophila [40].
Further research should focus on additional sampling throughout the mine, including the underground levels of the mine, where miners can spend part of their work shift. Non-potable water samples pre- and post-chlorine treatment should be assessed to determine the concentrations of chlorine necessary to prevent L. pneumophila from colonizing the distribution system.

Author Contributions

V.M.-G., N.L.-G. and P.I.B. designed research; V.M.-G. collected data; J.W. assisted data collection. V.M.-G., A.L.M. and M.H.W. analyzed data. V.M.-G., A.L.M., N.L.-G., M.H.W., P.I.B. and M.P.V. wrote the paper. All authors read and approved the final manuscript.

Funding

This research received no external funding.

Acknowledgments

This work was supported by the Southwest Environmental Health Sciences Center (NIEHS P30 ES006694). This publication’s contents are solely the responsibility of the authors and do not necessarily represent the official views of the National Institutes of Health.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Pruckler, J.M.; Forster, T.S.; Donlan, R.M.; Brown, E.; Murga, R.; Fields, B.S. Role of biofilms in the survival of Legionella pneumophila in a model potable-water system. Microbiology 2001, 147, 3121–3126. [Google Scholar]
  2. Fields, B.S.; Benson, R.F.; Besser, R.E. Legionella and Legionnaires’ Disease: 25 Years of Investigation. Clin. Microbiol. Rev. 2002, 15, 506–526. [Google Scholar] [CrossRef]
  3. Leoni, E.; De Luca, G.; Legnani, P.; Sacchetti, R.; Stampi, S.; Zanetti, F. Legionella waterline colonization: Detection of Legionella species in domestic, hotel and hospital hot water systems. J. Appl. Microbiol. 2005, 98, 373–379. [Google Scholar] [CrossRef] [PubMed]
  4. Van Der Kooij, D.; Veenendaal, H.R.; Scheffer, W.J. Biofilm formation and multiplication of Legionella in a model warm water system with pipes of copper, stainless steel and cross-linked polyethylene. Water Res. 2005, 39, 2789–2798. [Google Scholar] [CrossRef] [PubMed]
  5. Hines, S.A.; Chappie, D.J.; Lordo, R.A.; Miller, B.D.; Janke, R.J.; Lindquist, H.A.; Fox, K.R.; Ernst, H.S.; Taft, S.C. Assessment of relative potential for Legionella species or surrogates inhalation exposure from common water uses. Water Res. 2014, 56, 203–213. [Google Scholar] [CrossRef] [PubMed]
  6. Mathys, W.; Stanke, J.; Harmuth, M.; Junge-Mathys, E. Occurrence of Legionella in hot water systems of single-family residences in suburbs of two German cities with special reference to solar and district heating. Int. J. Hyg. Environ. Health 2008, 211, 179–185. [Google Scholar] [CrossRef]
  7. Sungur, E.I.; Cotuk, A. Enumeration of Legionella pneumophila in cooling tower water systems. Environ. Monit. Assess. 2005, 100, 53–58. [Google Scholar]
  8. Wadowsky, R.M.; Wolford, R.; McNamara, A.M.; Yee, R.B. Effect of temperature, pH, and oxygen level on the multiplication of naturally occurring Legionella pneumophila in potable water. Appl. Environ. Microbiol. 1985, 49, 1197–1205. [Google Scholar] [Green Version]
  9. Agresta, M.D.; Hanley, E.M.; Urquhart, K.; Schoonmaker, D.; Venezia, R.A. Nosocomial Legionellosis Associated with Aspiration of Nasogastric Feedings Diluted in Tap Water. Infect. Control Hosp. Epidemiol. 1994, 15, 529–533. [Google Scholar]
  10. Edwards, M.L.; Smith, D.W.; Muller, D. Changes in Iron and Transferrin Levels and Body Temperature in Experimental Airborne Legionellosis. J. Infect. Dis. 1983, 147, 302–307. [Google Scholar]
  11. Fitzgeorge, R.B.; Baskerville, A.; Broster, M.; Hambleton, P.; Dennis, P.J. Aerosol infection of animals with strains of Legionella pneumophila of different virulence: Comparison with intraperitoneal and intranasal routes of infection. J. Hyg. 1983, 90, 81–89. [Google Scholar] [CrossRef] [PubMed]
  12. Kim, B.; Anderson, J.; Mueller, S.; Gaines, W.; Kendall, A. Literature review—Efficacy of various disinfectants against Legionella in water systems. Water Res. 2002, 36, 4433–4444. [Google Scholar] [CrossRef]
  13. Prostański, D. Use of Air-and-Water Spraying Systems for Improving Dust Control in Mines. J. Sustain. Min. 2013, 12, 29–34. [Google Scholar] [CrossRef] [Green Version]
  14. Shevenell, L.; A Connors, K.; Henry, C.D. Controls on pit lake water quality at sixteen open-pit mines in Nevada. Appl. Geochem. 1999, 14, 669–687. [Google Scholar] [CrossRef]
  15. Bartie, C.; Klugman, K.P. Exposures to Legionella pneumophila and Chlamydia pneumoniae in South African Mine Workers. Int. J. Occup. Environ. Health 1997, 3, 120–127. [Google Scholar] [CrossRef] [PubMed]
  16. Davies, D.H.; Hill, E.C.; Howells, C.H.; Ribeiro, C.D. Legionella pneumophila in coal miners. Occup. Environ. Med. 1985, 42, 421–425. [Google Scholar] [CrossRef]
  17. Haas, C.N.; Rose, J.B.; Gerba, C.P. Quantitative Microbial Risk Assessment; Wiley: New York, NY, USA, 1999. [Google Scholar]
  18. Schoen, M.E.; Ashbolt, N.J. An in-premise model for Legionella exposure during showering events. Water Res. 2011, 45, 5826–5836. [Google Scholar] [CrossRef]
  19. Rose, J.B. Future health assessment and risk-management integration for infectious diseases and biological weapons for deployed US forces. In Strategies to Protect the Health of Deployed U.S. Forces: Assessing Health Risks to Deployed U.S. Forces: Workshop Proceedings; National Academies Press: Washington, DC, USA, 2000; pp. 59–112. [Google Scholar]
  20. Weir, M.H. Dose-response modeling and use: Challenges and uncertainties in environmental exposure. In Manual of Environmental Microbiology, 4th ed.; American Society of Microbiology: Washington, DC, USA, 2016. [Google Scholar]
  21. CDC. Sampling Procedure and Potential Sampling Sites. Available online: https://www.cdc.gov/legionella/health-depts/environmental-inv-resources.html (accessed on 9 February 2017).
  22. IDEXX. Legiolert. Available online: https://idexxcom-live-b02da1e51e754c9cb292133b-9c56c33.aldryn-media.com/filer_public/cb/ee/cbee9faf-58a4-4068-8dce-077e3e21da86/legiolert-procedure-insert.pdf (accessed on 26 March 2017).
  23. R-Core-Team. R: A Language and Environment for Statistical Computing; The R Development Core Team: Vienna, Austria, 2008. [Google Scholar]
  24. Kuiper, M.W.; Wullings, B.A.; Akkermans, A.D.L.; Beumer, R.R.; Van Der Kooij, D. Intracellular Proliferation of Legionella pneumophila in Hartmannella vermiformis in Aquatic Biofilms Grown on Plasticized Polyvinyl Chloride. Appl. Environ. Microbiol. 2004, 70, 6826–6833. [Google Scholar] [CrossRef]
  25. National-Center-for-Environmental-Assessment. Exposure Factors Handbook, 2011 ed.; National Center for Environmental Assessment; Office of Research and Development; U.S. Environmental Protection Agency: Washington, DC, USA, 2011.
  26. Chattopadhyay, S.; Perkins, S.D.; Shaw, M.; Nichols, T.L. Evaluation of Exposure to Brevundimonas diminuta and Pseudomonas aeruginosa during Showering. J. Aerosol Sci. 2017, 114, 77–93. [Google Scholar] [CrossRef]
  27. Zhou, Y.; Benson, J.M.; Irvin, C.; Irshad, H.; Cheng, Y.-S. Particle Size Distribution and Inhalation Dose of Shower Water under Selected Operating Conditions. Inhal. Toxicol. 2007, 19, 333–342. [Google Scholar] [CrossRef]
  28. Armstrong, T.W.; Haas, C.N. Legionnaires’ disease: Evaluation of a quantitative microbial risk assessment model. J. Water Health 2008, 6, 149–166. [Google Scholar] [CrossRef] [PubMed]
  29. Haagsma, J.A.; Graetz, N.; Bolliger, I.; Naghavi, M.; Higashi, H.; Mullany, E.C.; Abera, S.F.; Abraham, J.P.; Adofo, K.; Alsharif, U.; et al. The global burden of injury: Incidence, mortality, disability-adjusted life years and time trends from the Global Burden of Disease study 2013. Inj. Prev. 2016, 22, 3–18. [Google Scholar] [CrossRef] [PubMed]
  30. CDC. Legionellosis—United States, 2000–2009; 0149-2195; Centers for Disease Control and Prevention: Atlanta, GA, USA, 2011; pp. 1083–1086.
  31. Aminossadati, S.; Hooman, K. Numerical Simulation of Ventilation Air Flow in Underground Mine Workings; The University of Nevada: Reno, NV, USA, 2008. [Google Scholar]
  32. De Souza, E. Application of ventilation management programs for improved mine safety. Int. J. Min. Sci. Technol. 2017, 27, 647–650. [Google Scholar] [CrossRef]
  33. Tickner, J.A.; Ager, B.P. The control of microbiological hazards associated with air-conditioning and ventilation systems. Ann. Occup. Hyg. 1983, 27, 341–358. [Google Scholar]
  34. Dondero, T.J.; Rendtorff, R.C.; Mallison, G.F.; Weeks, R.M.; Levy, J.S.; Wong, E.W.; Schaffner, W. An Outbreak of Legionnaires’ Disease Associated with a Contaminated Air-Conditioning Cooling Tower. N. Engl. J. Med. 1980, 302, 365–370. [Google Scholar] [CrossRef]
  35. Ambrose, J.; Hampton, L.M.; Fleming-Dutra, K.E.; Marten, C.; McClusky, C.; Perry, C.; Clemmons, N.A.; McCormic, Z.; Peik, S.; Mancuso, J.; et al. Large outbreak of Legionnaires’ disease and Pontiac fever at a military base. Epidemiol. Infect. 2014, 142, 2336–2346. [Google Scholar] [CrossRef]
  36. Den Boer, J.W.; Yzerman, E.P.F.; Schellekens, J.; Lettinga, K.D.; Boshuizen, H.C.; Van Steenbergen, J.E.; Bosman, A.; Van den Hof, S.; Van Vliet, H.A.; Peeters, M.F.; et al. A large outbreak of Legionnaires’ disease at a flower show, the Netherlands, 1999. Emerg. Infect. Dis. 2002, 8, 37–43. [Google Scholar] [CrossRef]
  37. Gilmour, M.W.; Bernard, K.; Tracz, D.M.; Olson, A.B.; Corbett, C.R.; Burdz, T.; Ng, B.; Wiebe, D.; Broukhanski, G.; Boleszczuk, P.; et al. Molecular typing of a Legionella pneumophila outbreak in Ontario, Canada. J. Med. Microbiol. 2007, 56, 336–341. [Google Scholar] [CrossRef] [Green Version]
  38. Principe, L.; Tomao, P.; Visca, P. Legionellosis in the occupational setting. Environ. Res. 2017, 152, 485–495. [Google Scholar] [CrossRef]
  39. Berjeaud, J.-M.; Chevalier, S.; Schlusselhuber, M.; Portier, E.; Loiseau, C.; Aucher, W.; Lesouhaitier, O.; Verdon, J. Legionella pneumophila: The Paradox of a Highly Sensitive Opportunistic Waterborne Pathogen Able to Persist in the Environment. Front. Microbiol. 2016, 7, 21660. [Google Scholar] [CrossRef]
  40. Occupational-Safety-and-Health-Administration. Legionellosis (Legionnaire’s Disease and Pontiac Fever). Available online: https://www.osha.gov/SLTC/legionnairesdisease/standards.html (accessed on 26 August 2018).
Figure 1. Diagram of water distribution system and sampling sites at the studied mine.
Figure 1. Diagram of water distribution system and sampling sites at the studied mine.
Water 11 01528 g001
Figure 2. Average L. pneumophila concentrations on water storage level (n = 1), adit level (n = 3), and exterior level (n = 3).
Figure 2. Average L. pneumophila concentrations on water storage level (n = 1), adit level (n = 3), and exterior level (n = 3).
Water 11 01528 g002
Figure 3. Moderate disability adjusted life years (DALYs) for male and female miners.
Figure 3. Moderate disability adjusted life years (DALYs) for male and female miners.
Water 11 01528 g003
Figure 4. Severe DALYs for male and female miners.
Figure 4. Severe DALYs for male and female miners.
Water 11 01528 g004
Figure 5. Sequela DALYs for male and female miners.
Figure 5. Sequela DALYs for male and female miners.
Water 11 01528 g005
Table 1. Parameters used in the quantitative microbial risk assessment (QMRA) model.
Table 1. Parameters used in the quantitative microbial risk assessment (QMRA) model.
LabelVariableValueUnitDistributionReference
CL,SConcentration of L. pneumophila in non-potable water from the sprinkler system8.35 × 10−4Most probable number (MPN)/LN/AResults of this study
PCAir partitioning coefficient10−5UnitlessN/A[26]
VSWater volume released from the sprinkler system573L/sN/AProvided by the mine
FAFraction of aerosolized organismsMean: 0.0337
Std: 0.0098
UnitlessNormal[27]
Vm,airArea of the mine3.0 × 10−4LN/AProvided by the mine
VvVolume of air removed by the ventilation fan 5663L/sN/AProvided by the mine
CL, JDConcentration of L. pneumophila in non-potable water from the jackleg drill4.65 × 10−4MPN/LN/AResults of this study
VJDFlow of water released from the jackleg drill573L/sN/AProvided by the mine
ImaleInhalation rate for male workersMean: 0.02333
Std: 0.00434
m3/minNormal[25]
IfemaleInhalation rate for female workersMean: 0.02083
Std: 0.0056
m3/minNormal[25]
kProbability of the pathogen surviving to initiate infection in the host−0.00599UnitlessN/A[28]
DWPFDisability weight for Pontiac Fever
(moderate)
Mean: 0.051
Lower: 0.039
Upper: 0.06
UnitlessTriangular[29]
DWLDDisability weight for Legionnaires’ disease (severe)Mean: 0.125
Lower: 0.104
Upper: 0.152
UnitlessTriangular[29]
DWPCDisability weight for sequela
(post-acute)
Mean: 0.217
Lower: 0.179
Upper: 0.251
UnitlessTriangular[29]
Table 2. Water quality measurements and the concentration of L. pneumophila in non-potable water sources.
Table 2. Water quality measurements and the concentration of L. pneumophila in non-potable water sources.
Sampling LocationWater temperature
(°C)
Chlorine levels
(mg/L)
Average Concentration of L. pneumophila
(MPN/L)
Categories of Sampling Location by Mine Levels
Non-potable water tank23.6ND1.50 × 104Water Storage Level
Jackleg drill connection 21.6ND4.65 × 104Adit Level
Sprinkler system 21.1ND8.35 × 104Adit Level
Jackleg drill hose outside adit level30.9ND1.55 × 104Adit Level
Sink in hoist house19.00.052.50 × 104Exterior Level
Swamp cooler 16.80.054.00 × 104Exterior Level
Jackleg drill hose in hoist house23.3ND2.50 × 104Exterior Level
ND: Not detected.

Share and Cite

MDPI and ACS Style

Madera-García, V.; Mraz, A.L.; López-Gálvez, N.; Weir, M.H.; Werner, J.; Beamer, P.I.; Verhougstraete, M.P. Legionella pneumophila as a Health Hazard to Miners: A Pilot Study of Water Quality and QMRA. Water 2019, 11, 1528. https://doi.org/10.3390/w11081528

AMA Style

Madera-García V, Mraz AL, López-Gálvez N, Weir MH, Werner J, Beamer PI, Verhougstraete MP. Legionella pneumophila as a Health Hazard to Miners: A Pilot Study of Water Quality and QMRA. Water. 2019; 11(8):1528. https://doi.org/10.3390/w11081528

Chicago/Turabian Style

Madera-García, Valerie, Alexis L. Mraz, Nicolás López-Gálvez, Mark H. Weir, James Werner, Paloma I. Beamer, and Marc P. Verhougstraete. 2019. "Legionella pneumophila as a Health Hazard to Miners: A Pilot Study of Water Quality and QMRA" Water 11, no. 8: 1528. https://doi.org/10.3390/w11081528

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop